Segmented Design The Micropure Segmented design (shown above) offers significant advantages over conventional filter cartridges. Air or gas flows through the filter media into an adjacent segment. Filtered air or gas exits through openings at the center of the cartridge and out the sterile side of the housing.

Why you need sterile gas

To reduce batch contamination, spoilage and product loss, effective sterile gas filtration is a necessary part of your process. Especially important in the food, beverage, and pharmaceutical industries, sterile gas filtration protects your product from harmful submicron particle contamination and bacterial transfer or growth.

It also helps protect production yield, especially in high-tech industries (electronics, plating, magnetic media, etc.) where submicron particle contamination can significantly reduce yields, resulting in product and dollar loss. The use of high efficiency submicron gas filters have become a standard "current good manufacturing practice" allowing for more productive and economical processing.

How MicroPure Sterile Gas Filters do it better

System Security

Application Versatility

Unlimited Reusability MiroPure Segmented Filters

Economical

Convenience

MicroPure Segmented Filters feature a patented design that offers significant advantages over conventional filter cartridges. 

Self-sealing PTFE membranes with a 0.1 micron retention efficiency for gas are sandwiched between perforated stainless steel segments within an stainless steel housing.  The independently functioning modular segments are clamped together by a stainless steel tension rod that provides continued support upstream and downstream of the filter membrane.  The required cartridge length and diameter are determined by your application.

Unlike conventional pleated cartridges that degrade with each sterilization, MicroPure filters can be steam sterilized in place up to 150 times with no loss of filtering effectiveness, as validated by an internationally recognized food laboratory. Other sterilization or cleaning methods commonly used are autoclave, hydrogen peroxide, steam, or a variety of sanitizing agents.*

When membrane replacement becomes necessary, the operational-and disposal-cost is considerably lower than for other filters.   With MicroPure filters, only the small membrane media are replaced-not the entire cartridge.

Due to the porosity of our double-layer PTFE membrane, MicroPure filters permit higher flow rates than conventional filters, while maintaining submicron, bacterial retention efficiency.**
The rugged, reliable design of MicroPure Segmented Filters has been subjected to extensive testing in Europe and the United States, with more than 5,000 systems installed in food-and beverage-processing applications.

The results are unquestionable: MicroPure Segmented Filters, designed for two-way flow, ensureconsistent, uncompromised security for any application.

No other filter offers this combination of features:

-allows for bi-directional flow
-Clean-in-place with steam (150 times) or common sanitizing agent*

-broad range of chemical compatibility
-autoclavable, high temperature tolerance
-low extractable levels

-low replacement cost compared to conventional cartridge
-Simple, on-site visual inspection or “plating” or individual filter membrane; easily removable for laboratory analysis or culture.

*Check for chemical compatibility of PTFE prior to selecting a sanitizing agent.
**Reference laboratory report RP5268-challenge organism
bacillus Stearothermophilus at a concentration of 1 x 105 spores/ml.

Technical Data

Maximum Operating Pressure 232 psig 16 bar
Maximum Differential Pressure 75   psid 5.2 bar
Maximum Reverse Pressure 75   psid 5.2 bar
Pore Sizes .1 micron absolute.
(Other sizes available upon request)
Material of Construction:
Housing 304 SS
Segmented Filter Discs 304 SS
Filter Media 304 SS
O-Rings EPDM

Applications

Warranty

Micropure Filtration, Inc. provides a five year limited warranty on all parts except O-rings and media. A one year warranty on filter media is based a maximum loading of 140 million particles per cubic meter (normal conditions).   These warranties extend only to media purchased from Micropure or a certified Micropure Filtration Vendor.